HP 3PAR Solaris Implementation Guide

6 Configuring the Host for an FCoE Connection
This chapter describes the procedures that are required to set up a Solaris host to communicate
with an HP 3PAR StoreServ Storage over an FCoE initiator on the Solaris host to an FC target on
the HP 3PAR StoreServ Storage.
Solaris Host Server Requirements
To use an FCoE connection, the Solaris host must meet the following software requirements:
Solaris 11
Solaris 10 (MU9 and later)
Patches are downloadable from the following website:
Oracle
The following example shows how to generate the output for checking the current version levels
for various components:
bash-3.00# more /etc/release
Oracle Solaris 10 9/10 s10s_u9wos_14a SPARC
Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
Assembled 11 August 2010
Configuring the FCoE Switch and FC Switch
Connect the Solaris (FCoE Initiator) host ports to the FCoE-enabled switch and connect the HP 3PAR
StoreServ Storage server (FC target) ports of an FC switch.
NOTE: The FCoE switch must be able to convert FCoE traffic to FC and must also be able to trunk
this traffic to the fabric that the HP 3PAR StoreServ Storage target ports are connected to. FCoE
switch routing setup and configuration is beyond the scope of this guide. Consult your switch
manufacturer's documentation for instructions.
Configuring an HP 3PAR StoreServ Storage Port for an FCoE Host
Connection
There are no special configuration requirements for the HP 3PAR StoreServ Storage ports to be
able to connect a host with a CNA card configured with FCoE. As far as the HP 3PAR StoreServ
Storage is concerned, the initiator coming from the FCoE card through the FCoE Forwarder switch
is treated like another FC device connecting to the HP 3PAR StoreServ Storage ports.
When a server with a CNA card configured with FCoE is connected to HP 3PAR StoreServ Storage
ports, follow the same guidelines as for configuring the HP 3PAR StoreServ Storage and host for
FC connections:
“Configuring the HP 3PAR StoreServ Storage for Fibre Channel” (page 8)
“Configuring the Host for a Fibre Channel Connection” (page 28)
For specific configurations that support FCoE CNAs and forwarder switches, see the appropriate
HP 3PAR OS release version on the HP SPOCK website:
HP SPOCK
Configuring a CNA and FCoE Forwarder Switch
All guidelines in “Configuring the HP 3PAR StoreServ Storage for Fibre Channel” (page 8) apply
to FCoE connectivity as well.
Solaris Host Server Requirements 39