HP 3PAR StoreServ 7000 Storage Troubleshooting Guide

0:2 2000001862953303 Green 35 0xdc Loop fail 0xdc OK
0:3 2000001862953888 Green 31 0xda Loop fail 0xda OK
cli% showcage -sfp cage4
Cage FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
4 0 0 OK FINISAR CORP. 4.1 No No Yes Yes
4 1 1 OK FINISAR CORP. 4.1 No No No Yes
cli% showcage -sfp -ddm cage4
---------Cage 4 Fcal 0 SFP 0 DDM----------
-Warning- --Alarm--
--Type-- Units Reading Low High Low High
Temp C 33 -20 90 -25 95
Voltage mV 3147 2900 3700 2700 3900
TX Bias mA 7 2 14 1 17
TX Power uW 394 79 631 67 631
RX Power uW 0 15 794 10* 1259
---------Cage 4 Fcal 1 SFP 1 DDM----------
-Warning- --Alarm--
--Type-- Units Reading Low High Low High
Temp C 31 -20 90 -25 95
Voltage mV 3140 2900 3700 2700 3900
TX Bias mA 8 2 14 1 17
TX Power uW 404 79 631 67 631
RX Power uW 402 15 794 10 1259
Cage Example 2
Component -------------Description-------------- Qty
Cage Degraded or failed cage power supplies 2
Cage Degraded or failed cage AC power 1
Component -Identifier- ------------Description------------
Cage cage:1 Power supply 0 is Failed
Cage cage:1 Power supply 0's AC state is Failed
Cage cage:1 Power supply 2 is Off
Cage Suggested Action 2
A cage power supply or power supply fan has failed, is missing input AC power, or the switch is
turned OFF. The showcage -d cageX and showalert commands provide more detail.
cli% showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
1 cage1 0:0:2 0 1:0:2 0 24 27-39 2.37 2.37 DC2 n/a
-----------Cage detail info for cage1 ---------
Interface Board Info FCAL0 FCAL1
Link A RXLEDs Green Off
Link A TXLEDs Green Off
Link B RXLEDs Off Green
Link B TXLEDs Off Green
LED(Loop_Split) Off Off
LEDS(system,hotplug) Amber,Off Amber,Off
-----------Midplane Info-----------
Firmware_status Current
Product_Rev 2.37
State Normal Op
Loop_Split 0
Troubleshooting Storage System Components 31