HP 3PAR StoreServ 7000 Storage Troubleshooting Guide

Cage Example 4
SComponent ---------Description--------- Qty
Cage Cages not on current firmware 1
Component -Identifier- ------Description------
Cage cage:3 Firmware is not current
Cage Suggested Action 4
Check the drive cage firmware revision using the commands showcage and showcage -d
cageX. The showfirwaredb command displays current firmware level required for the specific
drive cage type.
NOTE: The DC1 and DC3 cages have firmware in the FCAL modules. The DC2 and DC4 cages
have firmware on the cage mid-plane. Use the upgradecage command to upgrade the firmware.
cli% showcage
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
2 cage2 2:0:3 0 3:0:3 0 24 29-43 2.37 2.37 DC2 n/a
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
cli% showcage -d cage3
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
-----------Cage detail info for cage3 ---------
.
.
.
-----------Midplane Info-----------
Firmware_status Old
Product_Rev 2.36
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC2
Unique_ID 10320300000AD100
cli% showfirmwaredb
Vendor Prod_rev Dev_Id Fw_status Cage_type Firmware_File
...
3PARDATA [2.37] DC2 Current DC2 /opt...dc2/lbod_fw.bin-2.37
Cage Example 5
Component -Identifier- ------------Description------------
Cage cage:4 Interface Card 0, SFP 0 is unqualified
Cage Suggested Action 5
In this example, a 2 Gb/s SFP was installed in a 4 Gb/s drive cage (DC4), and the 2 Gb/s SFP
is not qualified for use in this drive cage. For cage problems, the following CLI commands are
useful: showcage -d, showcage -sfp, showcage -sfp -ddm, showcage -sfp -d, and
showpd -state.
cli% showcage -d cage4
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
4 cage4 2:2:1 0 3:2:1 0 8 30-37 2.37 2.37 DC4 n/a
Troubleshooting Storage System Components 33