HP 3PAR StoreServ 7000 Storage Troubleshooting Guide

Table 2 Description of Controller Node Ports
PortItem
2 Ethernet
MGMT--Connects to the storage array management interfaces
1
RC--Connects to Remote Copy
Fibre Channel (FC-1 and FC-2)--Connects to host systems2
SAS (DP-2 and DP-1)--Connects the drive enclosures and I/O modules using
SAS cables
3
Node Interconnect--Connects four directional interconnect cables that connect
the controller nodes (four node 7400 only)
4
PCIe slot for optional four-port 8 Gb/s FC HBA or two-port 10 Gb/s CNA5
NOTE: The MFG port is not used.
I/O Modules
The I/O modules connect the controller nodes to the hard drives using a SAS cable and enabling
data transfer between the nodes, hard drives, PCMs, and enclosures. There are two I/O modules
located at the rear of the drive enclosure. There are two I/O modules per enclosure, numbered 0
and 1 from bottom to top. See Figure 6 (page 9).
Figure 6 I/O Module Numbering for HP M6710 (2U) and HP M6720 (4U) Drive Enclosures
NOTE: The I/O modules are located in slots 0 and 1 of the HP M6710 and M6720 drive
enclosures.
Power Cooling Modules
The PCM is an integrated power supply, battery, and cooling fan. There are two types of PCMs:
The 580 W is used in drive enclosures and does not include a battery.
The 764 W is used in node enclosures and includes a replaceable battery.
The PCMs are located at the rear of the storage system, and on the sides of the enclosure. There
are two PCMs per enclosure. The PCMs are numbered 0 and 1 from left to right.
Understanding Component Numbering 9