HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide F: 4 Node Systems with Mixed-Size Drive Enclosures

4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION: The Interconnect Cables are directional and labeled A and C.
4 Node 16 Drive Enclosures (6S+10L) 143