Brocade Access Gateway Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000633-01, June 2007)

Access Gateway Administrator’s Guide 19
53-1000633-01
Configuring port maps
4
2. Enter the switchShow command without any options to display the status of all ports.
switch:admin> switchshow
switchName: switch
switchType: 43.2
switchState: Online
switchMode: Access Gateway Mode
switchWwn: 10:00:00:05:1e:03:4b:e7
switchBeacon: OFF
Area Port Media Speed State Proto
=====================================
0 0 -- N4 No_Module
1 1 cu N4 Online F-Port 50:06:0b:00:00:3c:b7:32 0x5a0101
2 2 cu N4 Online F-Port 10:00:00:00:c9:35:43:f5 0x5a0003
3 3 cu N4 Online F-Port 50:06:0b:00:00:3c:b6:1e 0x5a0102
4 4 cu N4 Online F-Port 10:00:00:00:c9:35:43:9b 0x5a0002
5 5 cu N4 Online F-Port 50:06:0b:00:00:3c:b4:3e 0x5a0201
6 6 cu N4 Online F-Port 10:00:00:00:c9:35:43:f3 0x5a0202
7 7 cu AN No_Sync Disabled (Persistent)
8 8 cu N4 Online F-Port 10:00:00:00:c9:35:43:a1 0x5a0001
9 9 cu AN No_Sync Disabled (Persistent)
10 10 cu AN No_Sync Disabled (Persistent)
11 11 cu AN No_Sync Disabled (Persistent)
12 12 cu AN No_Sync Disabled (Persistent)
13 13 cu AN No_Sync Disabled (Persistent)
14 14 cu AN No_Sync Disabled (Persistent)
15 15 cu AN No_Sync Disabled (Persistent)
16 16 cu AN No_Sync Disabled (Persistent)
17 17 -- N4 No_Module
18 18 -- N4 No_Module
19 19 id N4 No_Light
20 20 -- N4 No_Module
21 21 id N4 Online N-Port 10:00:00:05:1e:35:10:1e 0x5a0200
22 22 id N4 Online N-Port 10:00:00:05:1e:35:10:1e 0x5a0100
23 23 id N4 Online N-Port 10:00:00:05:1e:35:10:1e 0x5a0000
Configuring port maps
In Access Gateway mode, the F_Ports are mapped to N_Ports. The first time Access Gateway mode
is enabled, the default F_Port to N_Port mapping is used. See Appendix A, “Default Port Mapping”.
This section explains how to change the mapping. When you update the mapping only the F_Ports
that are added or removed are affected.
NOTE
For bladed servers, the HBA connects to the internal ports. Therefore, the internal ports are F_Ports
and by default only the external ports are configured as N_Ports.
ADDING F_PORTS
Adding an F_Port to an N_Port routes that traffic to and from the fabric through the specified
N_Port. When failover is enabled and the N_Port goes offline or otherwise fails, the F_Port is
automatically routed to another N_Port that is connected to the same fabric.