Brocade Fabric Watch Administrator's Guide Supporting Fabric OS v6.0.0 (53-1000601-01, October 2007)

40 Fabric Watch Administrator’s Guide
53-1000601-01
Configuring Fabric Watch thresholds
3
Threshold boundary level is setat : Custom
DefaultCustom
Unit Percentage(%) Percentage(%)
Time base minuteminute
Low 0 0
High 100 80
BufSize 0 0
Threshold alarmlevel is set at: Custom
.
.
.
FIGURE 18 Changing the threshold alarm level
Figure 19 shows how to apply the custom value for the threshold alarm changes; unless you apply
the value, it does not take effect.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]16
.
.
.
FIGURE 19 Applying threshold alarm changes
NOTE
To ensure that your alarm setting configuration is in effect, remember to change the alarm level to
Custom and then apply the alarm settings.