Configuring Fabric Watch using SNMP
3
7. Obtain the specific identifier for the element that will be modified. To get the identifier, click the
swFwThresholdTable and swFwThresholdEntry directory, and run a get operation on
swFwName. A list of elements appears in which each element is preceded by an identifier.
Remember the numeric portion of the identifier, which appears before the “==>” symbol. You
can scroll through the list to find the numeric identifier for the element in which you are
interested.
Figure 28 shows a sample screen.
For detailed descriptions of the SNMP fields in both telnet and Web Tools, see the Fabric OS
MIB Reference.
FIGURE 29 Example swFwName screen
In this example, 83.1 is numeric identifier for the element referenced as resFlash000.
8. Traverse the fields beneath swFwClassAreaTable and swFwThresholdTable, appending the
numeric identifier from the previous step to each field before performing a get or write
operation. For example, to get and modify information specific to the resFlash000 element,
select one of the fields and append “83.1” in the Object ID field on the right side of the screen.
To modify information, you must define a write community. To modify an entry:
a. Select a field.
b. Append the numeric identifier to the Object ID.
c. Enter the new value into the Set Value field.
d. Select Set from the Operations menu.