Brocade Fabric Watch Administrator's Guide Supporting Fabric OS v6.0.0 (53-1000601-01, October 2007)

78 Fabric Watch Administrator’s Guide
53-1000601-01
SFP class
SFP class
Table 29 provides default settings for areas in the SFP class.
NOTE
SFPs connected to GbE ports are not monitored.
TABLE 29 SFP class threshold defaults
Area Description Default threshold settings Default alarm settings Threshold state
Current Monitors SFP current Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Receive Power Monitors receive
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Supply Voltage Monitors SFP
electrical force in
volt(s)
Unit: mV
Time Base: none
Low: 3150
High: 3600
Buffer: 10
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Temperature Monitors SFP
Temperature
Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Changed: 0
Below: 1
Above: 1
In-Between: 1
Informative
Out_of_range
Out_of_range
Normal
Transmit Power Monitors transmit
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Normal