Table 6 Fabric OS 6.3.2 closed defects (continued)
Fixed in Fabric OS 6.3.2.CALD terminated and logical switch delete failed with reason Could not
get port details from EM when attempting to delete two of six logical
switches in a DC SAN Backbone director from DCFM.
Fixed in Fabric OS 6.3.2.In AG mode, N_Port failover results in F_Ports with attached hosts getting
stuck as G_Ports. Occurs when there is a change in the base address for the
N_Port due to failover, or when there is no wwn-area mapping for few
devices and due to the login sequence of these devices. The PIDs assigned
conflicted with the already allocated PID to another device, resulting in the
F_Ports getting stuck as G_Ports.
Fixed in Fabric OS 6.3.2.Large core file fills up the compact flash and causes file system corruption.
If Fabric OS startup files are corrupted, the switch ends up in a reboot loop.
Fixed in Fabric OS 6.3.2.QoS circuits running over a 1 Gb/10 Gb bandwidth circuit on 1606
Extension switch or Extension blade will have incorrect QoS distributions
with large I/O. Occurs when running all three QoW priorities on a circuit
that is a multiple of 1 Gb/s and effects the distribution of traffic, which could
lead to performance issue.
Fixed in Fabric OS 6.3.2.Webd was seen to terminate from time to time, at the same time as HA status
temporarily went to non-redundant, triggering a Call Home event. Webd
was killed by a watchdog as it was waiting for a reply from a busy httpd
and did not have a timeout mechanism. No other functional impact observed
other than Call Home event.
Workaround prior to upgrade:
Triggering a warm boot on the switch
Multiple FCR masters in edge fabrics after ISL issues in the backbone.
that should not be FCR master (higher
WWN) should trigger it to recalculate
the FCR master.
Fixed in Fabric OS 6.3.2.
Fixed in Fabric OS 6.3.2.After firmware upgrade to Fabric OS 6.3.x, SNMP V3 requests are not
returned with correct values and V3 traps are not received.
Workaround prior to upgrade: Disable
FICON Emulation.
FICON Tape Emulation aborts from channel due to incorrect CCW number
in generated command retry status for write conv busy sequences. Channel
Fixed in Fabric OS 6.3.2.
Detected Error messages are seen for FICON Emulated tape devices during
tape pipelining, leading to some special tape media (WORM drives) being
unusable.
Fixed in Fabric OS 6.3.2.64 bit port stats are available only in CLI via portStats64Show, not
exposed through SNMP. Need to enhance SNMP code to expose these
counters.
Fixed in Fabric OS 6.3.2.Created a TI zone followed by cfgsave and cfgenable; zone -show
indicated that it was created, but later reissuance of zone -show did not
display the TI zone.
Workaround prior to upgrade: Do not
use TI zone with failover-disabled policy
TI zone with failover-disabled policy under base switch is not supported and
needs to be blocked. There are overlapping TI zones with failover-disabled
under base switch. With the codepolicy under LS partition in which one uses DISL connection and the other
change in this release, executing TI zoneuses XISL connection. When DISL connection gets disabled, there is no traffic
going through the XISL connection. command with failover-disabled policy
under base switch gets the response:
Cannot create TI zone with
failover flag disabled on a
base switch.
Fixed in Fabric OS 6.3.2.
Fixed in Fabric OS 6.3.2.The 1606 Extension switch does not support the Path Down function in IM2
mode. Fabric becomes unstable and segments when one leg of a TI Zone
with Failover Disabled is disrupted.
44