HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) (5697-0754, October 2010)

2 Preparing for the upgrade
Before starting the XCS upgrade, you should perform several tasks to minimize the time required to
complete the upgrade. The tasks you perform depend on your system configuration and the HP
Command View EVA implementation. These tasks focus on upgrading system components to ensure
they meet the supported configuration for XCS 09534000. Table 5 on page 46 provides a checklist
so you can track your progress as you perform these pre-upgrade tasks.
Checking the controller software version
Estimated time to complete: About 5 minutes
When to perform: Anytime before the upgrade
To check your controller software version, follow these steps:
1. Open HP Command View EVA.
2. In the navigation pane, select the array you plan to upgrade.
The Initialized Storage System Properties window opens. The version field shows the current
version.
Checking management software versions
Estimated time to complete: 1015 minutes
When to perform: Anytime before the upgrade
When upgrading the system software, you must upgrade related management software to the required
version. Use Table 2 on page 14 to collect version information for your current software.
HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) 13