HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) (5697-0754, October 2010)

.
11. In the Initialized Storage System Properties window, verify the version of the storage system
software in the Version box. It should be 09534000.
Figure 21 Verifying XCS version after upgrading
.
TIP:
After upgrading the controller software, consider the following:
If the array is initialized or re-initialized after the upgrade, the default Data Replication
Protocol will be HP SCSI FC Compliant Data Replication Protocol, which is not currently
supported in HP Continuous Access EVA configurations with EVAx000 or EVAx100
arrays. If the Data Replication Protocol is not compatible with the Data Replication Pro-
tocol of the other array in the HP Continuous Access EVA configuration, the data replic-
ation paths will be disabled until a compatible Data Replication Protocol is selected in
HP Command View EVA. To change the protocol default setting to HP FC Data Replication
Protocol, complete the following steps in HP Command View EVA:
1. In the navigation pane, select the Data Replication folder.
The Data Replication Properties Folder window opens in the content pane.
2. Select Data Replication Options.
The Data Replication Options window opens.
3. Select Set Data Replication Protocol.
The Data Replication Protocol options window opens.
4. Select HP FC Data Replication Protocol.
5. Select Save Changes.
On the EVA4400, if you notice the controller logs are not being retrieved correctly, see
Controller logs possibly retrieved incorrectly after upgrading to XCS 09534000 on the
EVA4400 in the
HP StorageWorks Enterprise Virtual Array Release Notes (XCS
09534000)
.
HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) 59