AB379A Fibre Channel Mass Storage Adapter Installation Guide HP-UX and OpenVMS Storage Manufacturing Part Number: AB379-96005 February 2007 Printed in the US © Copyright 2007 Hewlett Packard Development Company L.P.
Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Contents 1. Fibre Channel Adapter Installation for HP-UX Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Important Patches and Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installing Driver Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents 4
1 Fibre Channel Adapter Installation for HP-UX This chapter contains installation prerequisites, guidelines, and procedures for the AB379A host bus adapter.
Fibre Channel Adapter Installation for HP-UX Important Patches and Updates echo $PATH • Verify that you have the following items: — Grounding wrist strap — Fibre Channel driver software media (included with the OS or application CD) — Fibre Channel host bus adapter with an optical port protector attached (not included with all adapters) • Verify that you have the following cabling items: — Fiber optic cable terminated with a duplex LC connector.
Fibre Channel Adapter Installation for HP-UX Installing Driver Software Installing Driver Software NOTE Use the following instructions if the driver is provided on a CD-ROM. If the driver software is downloaded, follow the instructions provided with that file. The driver software, FibrChanl-01, may be downloaded from http://software.hp.com. The FibrChanl-01 bundle is also provided on the Operating Environment media or Application Release media for HP-UX 11i v3 and HP-UX 11i v2.
Fibre Channel Adapter Installation for HP-UX Installing Adapter Hardware /var/adm/sw/swinstall.log Step 15. Install OnlineDiag, which is available at http://www.software.hp.com. OnlineDiag is also available from the HP Support PLUS CD. Installation instructions are available at: http://docs.hp.com/hpux/onlinedocs/diag/st/st_inst.
Fibre Channel Adapter Installation for HP-UX Installing Adapter Hardware OnlineDiag is also available from the HP Support PLUS CD for HP/9000 systems or the IPFxxxx CD for Itanium systems. Installation instructions are available at: http://docs.hp.com/hpux/onlinedocs/diag/st/st_inst.htm Install all driver software and dependent patches before you install the adapter. For more information, see the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver Release Notes available at: http://docs.hp.com/en/netcom.
Fibre Channel Adapter Installation for HP-UX Installing Adapter Hardware Figure 1-1 10 AB379A Dual Port Fibre Channel Adapter Chapter 1
Fibre Channel Adapter Installation for HP-UX Attaching the Adapter to Other Fibre Channel Devices Attaching the Adapter to Other Fibre Channel Devices To attach the adapter to other Fibre Channel devices, follow these steps: 1. Remove the Fibre Channel host bus adapter’s optical port protector (if included). 2. Attach a connector cable to the Fibre Channel host bus adapter. a. Align the slotted plug with the keyed connector. b. Push the connector in until you hear it click. 3.
Fibre Channel Adapter Installation for HP-UX LED Interpretation The ioscan output might look like the following. The third column represents the hardware path of the slot in which the adapter is installed. This path will be different for each installed adapter port.
Fibre Channel Adapter Installation for HP-UX Obtaining Card Information after Installation Obtaining Card Information after Installation Example of Card information after Installation #fcmsutil /dev/fcd1 Vendor ID is = 0x001077 Device ID is = 0x002422 PCI Sub-system Vendor ID is = 0x00103c PCI Sub-system ID is = 0x0012d7 PCI Mode = PCI-X 133 MHz ISP Code version = 4.0.
Fibre Channel Adapter Installation for HP-UX Verifying Connectivity Engineering Date Code : A-4602 Part Serial number : US00016362 Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ Mfd. Date : 4602 Mfd. ID : FC2410401-10 04 Check Sum : 0xc5 EFI version : 01.01 ROM Firmware version : 04.00.70 BIOS version : 01.06 FCODE version : 01.
Fibre Channel Adapter Installation for HP-UX Interpreting Legacy Hardware Paths (HP-UX 11i v1 and 11i v2) Step 2. Verify that all devices you attached to the Fibre Channel adapter are listed in the ioscan output. For example, if you have a direct attach Fibre Channel device attached to the system, the ioscan output may look like the following: 8/12.8.0.255.0.1.
Fibre Channel Adapter Installation for HP-UX Interpreting Legacy Hardware Paths (HP-UX 11i v1 and 11i v2) Table 1-4 describes each field in the hardware path. Table 1-4 Hardware Path Field Descriptions Fibre Channel Topology of HBA Field Value Fabric Topologies Private Loop Adapter The hardware path of the Fibre Channel adapter through which the Logical Unit Number (LUN) is seen. For multiport adapters, this field describes a specific port on the adapter.
Fibre Channel Adapter Installation for HP-UX Interpreting Legacy Hardware Paths (HP-UX 11i v1 and 11i v2) Table 1-4 Hardware Path Field Descriptions (Continued) Fibre Channel Topology of HBA Field Target Value Depends on the Fibre Channel topology and the LUN addressing method used. Fabric Topologies Private Loop For LUNs with Peripheral Device Addressing, the value of this field is the lower 4-bits of the third byte of the N_Port ID of the target device.
Fibre Channel Adapter Installation for HP-UX Interpreting Lunpath Hardware Paths (HP-UX 11i v3) Interpreting Lunpath Hardware Paths (HP-UX 11i v3) Lunpath hardware paths are a new representation of hardware paths introduced on HP-UX 11i v3, as part of the new agile representation of mass storage devices. For more details, please refer to the Next Generation Mass Storage Stack HP-UX 11i v3 white paper at http://docs.hp.com/en/netsys.html#Storage%20Area%20Management .
Fibre Channel Adapter Installation for HP-UX Interpreting Lunpath Hardware Paths (HP-UX 11i v3) Target Node World Wide Name = 0x500805f300083890 The LUN address for a Fibre Channel device is a 64-bit LUNid.
Fibre Channel Adapter Installation for HP-UX Interpreting Lunpath Hardware Paths (HP-UX 11i v3) The controller, target, and lun values are extracted from the LUN id as shown in the table: Table 1-8 Controller (7 bits) Target (4 bits) 0-63 0-15 LUN (3 bits) 0-7 To convert a lunpath hardware path to a legacy hardware path, use the scsimgr get_info command on the target’s hardware path to display the port_id, which contains the domain, area, and port values.
2 Fibre Channel Adapter Installation for OpenVMS This chapter contains installation prerequisites, guidelines, and procedures for the AB379A host bus adapter.
Fibre Channel Adapter Installation for OpenVMS Installing Driver Software • Verify that you have the following cabling items: — Fiber optic cable terminated with a duplex LC connector. Cable must be 50 or 62.5 micron multimode cable. — Cable map (optional) Installing Driver Software The driver for the AB379A Fibre Channel Host Bus Adapter is included in the installation of OpenVMS Version 8.3 and later OpenVMS releases. To check for the latest software patches, search for OpenVMS at: http://www.itrc.hp.
Fibre Channel Adapter Installation for OpenVMS Installing Adapter Hardware Installing the Host Bus Adapter Step 1. Access the system card bay • • • • • If the system is running, enter this command to shut it down: @SYS$SYSTEM:SHUTDOWN Enter y when prompted to continue. Wait for the system to shut down completely, and then power off the system by pressing the system off button. Ensure that the system is grounded. Open the system to gain access to the PCI backplane.
Fibre Channel Adapter Installation for OpenVMS Attaching the Adapter to Other Fibre Channel Devices Attaching the Adapter to Other Fibre Channel Devices To attach the adapter to other Fibre Channel devices, follow these steps: 1. Remove the Fibre Channel host bus adapter’s optical port protector (if included). 2. Attach a connector cable to the Fibre Channel host bus adapter. a. Align the slotted plug with the keyed connector. b. Push the connector in until you hear it click. 3.
Fibre Channel Adapter Installation for OpenVMS Verifying the Fibre Channel Adapter Installation FC Port Name 5006-0B00-003B-48F4 FC Node Name 5006-0B00-003B-48F54. Device FGB0:, device type QLogic ISP24xx FibreChannel, is online, shareable, error logging is enabled.
Fibre Channel Adapter Installation for OpenVMS Additional Configuration Information Additional Configuration Information NOTE OpenVMS only supports Fibre Channel connection via a Fibre Channel switch. Arbitrated loop and point-to-point topologies are not supported. Review the Guidelines for OpenVMS Cluster Configurations located at: http://www.hp.com/go/openvms/doc for additional information about configuring and booting Fibre Channel devices on OpenVMS.
A Technical Specifications and Regulatory Information AB379A Technical Specifications Table A-1 Performance Characteristics Local bus mode and speed PCI-X 266MHz, PCI-X 133MHz, PCI-X 66MHz, PCI 66MHz, PCI 33MHz Connectivity Dual port Fibre Channel, multi-mode short-wave optical link Link Speed 4 Gbps / 2 Gbps / 1 Gbps Link Distance 4Gbps : 150m; 2Gbps : 300m; 1Gbps : 500m Over 50/125um multi-mode fiber optic cable Connector Two LC Duplex Connectors Bus Slot 3.
Technical Specifications and Regulatory Information FCC Statement (For U.S.A.) FCC Statement (For U.S.A.) Federal Communications Commission Radio Frequency Interference Statement WARNING This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that might cause undesired operation.
Technical Specifications and Regulatory Information VCCI (Japan) (PCI Card Only) VCCI (Japan) (PCI Card Only) This equipment complies with the Class A category for information technology equipment based on the rules of Voluntary Control Council for Interference by Information Technology Equipment. When used in a residential area, radio interference may be caused. In this case, the user may be required to take appropriate corrective actions.
Technical Specifications and Regulatory Information Laser Safety Statements CAUTION The optical transceiver provided on the network interface card contains a laser system and is classified as a “Class 1 Laser Product” per EN 60825-1, Safety of Laser products. Class 1 laser products are considered safe and do not pose a biological hazard if used within the data sheet limits and instructions.
Technical Specifications and Regulatory Information AB379A Declaration of Conformity AB379A Declaration of Conformity Appendix A 31
Technical Specifications and Regulatory Information AB379A Declaration of Conformity 32 Appendix A