AB379A Fibre Channel Mass Storage Adapter Installation Guide, February 2007

Fibre Channel Adapter Installation for HP-UX
Verifying Connectivity
Chapter 1
14
Engineering Date Code : A-4602
Part Serial number : US00016362
Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ
Mfd. Date : 4602
Mfd. ID : FC2410401-10 04
Check Sum : 0xc5
EFI version : 01.01
ROM Firmware version : 04.00.70
BIOS version : 01.06
FCODE version : 01.12
Asset Tag : NA
Example of ioscan entry after installation
fc 0 0/0/2/1/0 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre
Channel Adapter (FC Port 1)
/dev/fcd0
fc 1 0/0/2/1/1 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre
Channel Adapter (FC Port 2)
/dev/fcd1
fcp 0 0/0/2/1/1.97 fcd_fcp CLAIMED INTERFACE FCP Domain
ext_bus 2 0/0/2/1/1.97.5.19.0 fcd_vbus CLAIMED INTERFACE FCP Array Interface
target 11 0/0/2/1/1.97.5.19.0.0 tgt CLAIMED DEVICE
disk 11 0/0/2/1/1.97.5.19.0.0.0 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c2t0d0 /dev/rdsk/c2t0d0
disk 14 0/0/2/1/1.97.5.19.0.0.1 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c2t0d1 /dev/rdsk/c2t0d1
disk 18 0/0/2/1/1.97.5.19.0.0.2 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c2t0d2 /dev/rdsk/c2t0d2
disk 21 0/0/2/1/1.97.5.19.0.0.3 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c2t0d3 /dev/rdsk/c2t0d3
Verifying Connectivity
Once your HP Fibre Channel Mass Storage software and hardware is installed and running, follow these
steps to verify connectivity:
Step 1. Check the state of all Fibre Channel hardware and interfaces. Enter the ioscan command and
verify that the Hardware State and the HW-Interface State are CLAIMED.
If the Fibre Channel device file has not been created, enter the following commands:
# insf -e
# ioscan -f