HP 501 Wireless Client Bridge V1.0.0.0 Configuration and Administration Guide

50 Tools
RSSI threshold
When an RSSI value is detected that is lower than the configured RSSI threshold, the value is
stored in the RSSI log and, if Syslog mode is enabled, sent to the configured Syslog server.
Enter a value from –99 to –1 dBm. The default is –30 dBm.
Logging interval
The RSSI level is detected and logged at a regular interval. Enter the number of seconds
between log entries, from 1 to 3600 seconds.
Syslog mode
Select Enabled to have RSSI log entries sent to the configured Syslog server when the detected
RSSI value is below the threshold. Select Remote syslog configuration to display the
System log page.
RSSI log
The RSSI log shows the date of each RSSI entry, the MAC address of the remote AP, the channel
on which the signal was detected, and the RSSI value. Click Refresh to display the latest data
from the HP 501.