HP Power over Ethernet (PoE/PoE+) Planning and Implementation Guide
13-18
Planning and Implementation for the HP 5400zl/8200zl Switches
Planning the PoE Configuration
Power Configuration for HP 5406zl/8206zl
PoE/PoE+ Switches
Note Using PoE power supplies J8712A and J8713A with J9306A in PoE/PoE+
systems is NOT supported. Use the J9306A zl power supply for systems
providing both PoE and PoE+ power.
Table 13-6 shows the maximum PoE/PoE+ power available for various power
configurations.
Table 13-6. HP 5406zl/8206zl Power Configurations for PoE/PoE+
Mixed PoE Power
(NOT Recommended))
1 1 N+1 System and Redundancy -
up to 273 W, see page 13-
27
1173 W
(With External Power
Supplies Added>
3 0 N+1 Up to 546 W 819 W
4 0 Full Up to 546 W 1092 W
0 3 N+1 Up to 1800 W 2700 W
0 4 Full Up to 1800 W 3600 W
Switch Model
HP 5406zl/8206zl
Number of Power Supplies Redundancy Model Non-Redundant
Power Available
J8712A
(110 or 220 volts)
J8713A
(220 volts only)
N + 1
or
Full
Redundant PoE Power Non-Redundant
PoE Power
Switch Model
5406zl/8206zl
Number of Power Supplies
J9306A
Redundancy Model Non-Redundant
Power Available
@ 110 - 127 V @ 200-240 V N + 1 or
Full
Redundant PoE/PoE+
Power
Non-Redundant
PoE/PoE+ Power
PoE/PoE+ Power
(54v) Internal
1 0 - None 300 W
2 0 Full Up to 300 W 600 W
0 1 - None 900 W
0 2 Full Up to 900 W 1800 W