HP Power over Ethernet (PoE/PoE+) Planning and Implementation Guide

14-36
Planning and Implementation for the HP 5400R zl2 Switches
Configuration Examples
Note HP networking highly recommends that the three types of power supplies are
not mixed in the same HP 5412R zl2 Switch.
Although it is not recommended to mix power supplies, the following
configurations shown in the table can be included:
Source of Power
(PoE/PoE+)
Watts Available Number of Ports Powered and Average
watts/Port
Four Internal PoE
Power Supplies: two
J9828As and
two J9829As
2172 (without
redundancy)
72 @ average 30 W each
140 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Source of Power
(PoE/PoE+)
Watts Available
at 115-127V
Number of Ports Powered and Average watts/Port
Two PoE/PoE+
Power Supplies
(One J9829A and
one J9830A) P
3144 (without
redundancy)
104 @ average 30 W each
204 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Two PoE/PoE+
Power Supplies
(One J9828A and
one J9830A)
2566 (without
redundancy)
85 @ average 30 W each
166 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Three PoE/PoE+
Power Supplies
(One J9828A and
two J9830A)
4878 (without
redundancy)
162 @ average 30 W each
288 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Three PoE/PoE+
Power Supplies
(One J9829A and
two J9830A)
5456 (without
redundancy)
181 @ average 30 W each
288 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Four PoE/PoE+
Power Supplies
(Two J9828A and
two J9830A)
5132 (without
redundancy)
170 @ average 30 W each
288 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each
Four PoE/PoE+
Power Supplies
(Two J9829A and
two J9830A)
6288 (without
redundancy)
162 @ average 30 W each
288 @ average 15.4 W each
288 @ average 7.5 W each
288 @ average 4.0 W each