HP OpenFlow 1.3 Administrator Guide Wired Switches K/KA/KB/WB 15.15

5 Administering OpenFlow
Additional fields and filters added in OpenFlow version 1.3 increases the available show commands.
Monitoring OpenFlow
OpenFlow can be monitored at several levels and the rate at which the information from the
hardware is refreshed can be configured.
Displaying OpenFlow information
Displays the versions of OpenFlow instance with status and flow data.
Syntax
show openflow
Example
HP-Switch# show openflow
OpenFlow : Disabled
IP Control Table Mode : Enabled
Instance Information
No. of No. of OpenFlow
Instance Name Status H/W Flows S/W Flows Version
------------------- --------- ---------- --------- ---------
titan Down 0 0 1.0
marez Up 0 0 1.3 only
Setting OpenFlow statistics refresh rate
Choose the maximum time before hardware statistics are refreshed.
Syntax
openflow hardware-statistics refresh-rate secs
secs
The hardware statistics refreshrate for OpenFlow.
Default: 20 secondsRange: 0— 3600 seconds
NOTE: With value of 0, the hardware is no longer polled to update the
statistics.
Viewing OpenFlow information
You can display OpenFlow information for all instances, ports, and flows. The returned information
includes the OpenFlow version supported.
Syntax
show openflow [ resources | controllers | instance instance-name [[
port-statistics ] | flows [ flow-filters auxiliary-connections] ] ]
Show OpenFlow information.
resources
Shows OpenFlow resource utilization. See “Viewing OpenFlow resources
(page 40).
34 Administering OpenFlow