Possible connection states are Active, Idle, Backoff, Connecting, or Void.
Possible connection status values are Connected or Disconnected.
Viewing instance aggregate
Display information of an OpenFlow aggregate instance.
Example 4 Show OpenFlow instance aggregate
show openflow instance titan
Configured OF Version : 1.3
Negotiated OF Version : NA
OpenFlow Version : 1.3
Instance Name : titan
Admin. Status : Disabled
Member List : VLAN 1
Listen Port : 6633
Oper. Status : Down
Oper. Status Reason : No port in member VLAN
1
Datapath ID : 0000002320e52b88
Mode : NA
Flow Location : NA
No. of Hw Flows : 0
No. of Sw Flows : 0
Hw. Rate Limit : 0 kbps
Sw. Rate Limit : 100 pps
Conn. Interrupt Mode : Fail-Secure
Maximum Backoff Interval : 60 seconds
Probe Interval : 45 seconds
Hw. Table Miss Count : 100
2
No. of Sw Flow Tables : 4
3
Egress Only Ports : 1/11, 1/23, 1/24
4
Table Model : Single Table
5
Controller ID Connection Status Connection State Secure Role
6
------------- ----------------- ---------------- ------ ------
1 Connected Active Yes Master
2 Disconnected Void No Slave
Auxiliary Auxiliary Auxiliary
Controller ID Conn. index Auxiliary ID Conn. Status Conn. State Type
7
------------- ----------- ------------ ------------- -------------- ----
1 1 111 Connected Active TCP
2 2 121 NA Send Hello UDP
Viewing OpenFlow resources
Syntax
show openflow resources
1. Reason will be N/A when operational status is up.
2. Only for 1.0 instance. NA for 1.3 instance.
3. Only for 1.3 instance. NA for 1.3 instance.
4. “None” if no ports available.
5. “Single Table” for 1.0 instance. For 1.3 instance the values could be “Policy Engine and Software or IP Control With
Policy Engine and Software
6. Will be equal for 1.0 instance.
7. This table appears only for 1.3 instance.