HP Power over Ethernet (PoE/PoE+) Planning and Implementation Guide
14-27
Planning and Implementation for the HP 5400R zl2 Switches
Configuration Examples
All three modules can be used or six and a half modules (134 ports) at 7.5 watts
per port.
Two power supplies could be used to supply PoE power at 508 watts and the
other two power supplies could be held in reserve as redundant power
supplies if the primary power supplies fail. If two power supplies are
connected to different power sources, they could backup the other two in case
of failure. With this option the user must manage the PoE usage in order to
maintain redundancy.
3 254 watts for PoE per power supply
4 Back
Label Description
Source of Power
(PoE/PoE+)
Watts Available Number of Ports Powered and Average
watts/Port
Redundant Number of Ports Powered
and Average watts/Port
Four Internal
Power Supplies
(J9828A)
1016 (without
redundancy)
33 @ average 30 W each
65@ average 15.4 W each
134 @ average 7.5 W each
250@ average 4.0 W each
16 @ average 30 W each
32 @ average 15.4 W each
66 @ average 7.5 W each
123 @ average 4.0 W each