Event Log Message Reference Guide 2013/06

32
Event Log Messages
563 Port <port-num> PD MPS Absent
indication.
warning The switch no longer detects a powered device on the port. The
device may have been disconnected, powered down, or stopped
functioning.
RMON_POEMGR_PD_MPS_ABSENT
564 Port <port-num> PD Invalid
Signature indication.
warning The switch has detected a non-802.3af-compliant device on the
port. This message appears for all non-802.3af devices connected
to the port, such as other switches and PC-NICs.
RMON_POEMGR_PD_INVALID_SIG
565 Port <port-num> PD Removed. info The powered device connected to the port has been removed.
RMON_POEMGR_PD_REMOVED
566 Port <port-num> PD Denied
power due to insufficient power
allocation.
warning There is insufficient power available to power the PD on the port
and the port does not have sufficient PoE priority to take power
from another active PoE port.
RMON_POEMGR_PD_DENIED_POWER
567 Port <port-num> PD Other Fault
indication.
warning There is a problem with the PD connected to the port.
RMON_POEMGR_PD_OTHER_FAULT
568 <slot-num> Ext Power Supply
connected, supplying <num> W
of <num> W max.
info The external power supply installed in the slot is providing the
displayed amount of total power required.
RMON_POEMGR_EPS_CONNECTED
569 <slot-num> Ext Power Supply:
<eps-type> Failures: <num>.
warning A fault condition has been detected on the external power supply
installed in the slot. The number of power failures is displayed.
Potential Cause and Resolution:
This may have been caused by a switch that was currently
drawing PoE power (50v) requiring the additional power supplied
by the External Power Supply. When the switch internal power
supply failed, this caused an overcurrent situation and the
External Power Supply may now need to be reset (unplugged,
plugged back in) to bring it back online.
RMON_POEMGR_EPS_ERROR
570 <slot-num> Ext Power Supply
connected but not responding.
warning The external power supply installed in the slot is installed but not
responding to communication attempts.
RMON_POEMGR_EPS_COMM_FAULT
571 — —
RMON_POEMGR_USAGE_THRESH_EXCEEDED
572 Slot <slot-num> POE usage has
exceeded threshold of <1-99>%.
warning POE usage in the slot has exceeded the configured threshold for
the module, as set by the “power threshold” or “power slot <slot-
num> threshold” command. (The switch also generates an SNMP
trap for this event.)
RMON_POEMGR_SLOT_USAGE_THRESH_EXCEEDED
573 <slot-num> Ext Power Supply
disconnected.
warning The external power supply installed in the specified slot is no
longer connected.
RMON_POEMGR_EPS_DISCONNECTED