Event Log Message Reference Guide 2013/06

33
Event Log Messages
574 Slot <slot-num> POE usage is
below configured threshold of
<1-99>%
warning POE usage on the specified module has a configured threshold of
<1-99>%, which has decreased below the threshold value set by
the “power threshold” command. This message occurs if, after
the last reboot, the PoE demand on the module exceeded the
power threshold and then later dropped below the threshold
value.
RMON_POEMGR_SLOT_USAGE_UNDER_THRESH
575 <slot-num> EPS not supported by
switch code. Please update.
warning The external power supply installed in the slot is not supported by
the current software release.
RMON_POEMGR_EPS_NOT_SUPPORTED
576 50V Power Supply is faulted.
Failures: x
50V Power Supply is OK.
Failures: x
warning Internal power supply has faulted.
Internal power supply is now operational.
RMON_POEMGR_INTERNAL_50V_FAULT
577 Ext Power Supply: <slot-num>
Failures: <num>.
fatal The power supply installed in the slot has failed. There is a danger
of possible damage to the chassis. The number of power failures
is displayed.
RMON_POEMGR_EPS_FATAL_ERROR
578 <slot-num> Unrecoverable fault
on PoE controller <controller-id>.
warning An error condition has been detected on the PoE controller on the
module in the slot.
RMON_POEMGR_CONTROLLER_FAULT
579 Slot <slot-num> Software update
started on PoE controller
<controller-id>
and
Slot <slot-num> Software update
completed on PoE controller
<controller-id>
info A module needs to have its PoE firmware updated and the PoE
controller software begins the update process. On Series 5400zl
switches, the <controller-id> value is always “1”
A module has its PoE firmware updated and the software has
finished this process.
RMON_POEMGR_FIRMWARE_UPDATE
580 info Reserved
RMON_POEMGR_RESERVED6
581 Invalid VLAN <vlan-id> supplied
for port <port-num>
info During web or MAC authentication, an invalid port assignment
has been detected for the VLAN ID.
RMON_WEBMAC_AUTH_BAD_VLAN
582 <num> auth-timeouts for the last
<num> secs.
info During web or MAC authentication, no server response has been
received and the authentication request has timed out for the
specified number of times during this time period.
RMON_WEBMAC_AUTH_GENSTAT_TO
583 <num> auth-failures for the last
<num> secs.
info The specified number of failures have occurred for web or MAC
authentication requests during this time period.
RMON_WEBMAC_AUTH_GENSTAT_FL
584 Port <port-num>, re-auth timeout
<num> too short.
info The configured timeout period (in seconds) for performing a re-
authentication request on the port is too small.
RMON_WEBMAC_AUTH_INVALID_RTO
# Message Severity Description