Event Log Message Reference Guide 2013/06

69
Event Log Messages
2768 Port <port-num> PoE power
dropped. Exceeded physical
classification for a PoE Type1
device.
warn LLDP is disabled at runtime and the PD was draining PoE+ power
negotiated through LLDP.
RMON_POE_RESTRICT_PWR_FOR_TYPE1_PD
2769 Ext Power Supply <power-
supply> measured out of spec or
is faulty. Please change or
contact
warn An EPS is plugged in and the software reads invalid isrc value.
RMON_POEMGR_EPS_INVALID_ISRC
2770 Port <port-num> EEE disabled
due to Polarity Error found on the
cable. Correct the polarity.
warn A cable is found with pairA/pairB polarity swapped. Correct the
polarity.
RMON_PPMGR_PORT_BAD_POLARITY
2771 Port <port-num> PoE power
dropped. Exceeded physical
classification due to change in
classification type.
warn LLDP is enabled at runtime and the PD was draining PoE+ power
that exceed the physical classification because the classification
type was changed.
RMON_POE_RESTRICT_PWR_FOR_TYPE2_PD
2778 Internal power supply <pwr-
supply>: Fan <fan-id> failed.
warn A fan on an internal power supply failed. The power supply still
provides power and is not shut down.
RMON_IPS_FAN_FAILURE_WARN
2779 Internal power supply <pwr-
supply>: Output power exceeded
threshold.
warn The power supply’s output has exceeded the threshold. The
power supply still supplies power and is not shut down.
RMON_IPS_OUTPUT_PWR_EXCEEDED_WARN
2780 Internal power supply <pwr-
supply>: System current
exceeded threshold.
warn The power supply’s system current has exceeded the threshold.
The power supply still supplies power and is not shut down.
RMON_IPS_SYS_CURRENT_EXCEEDED_WARN
2781 Internal power supply <pwr-
supply>: PoE current exceeded
threshold
warn The power supply’s PoE current has exceeded the threshold. The
power supply still supplies power and is not shut down.
RMON_IPS_POE_CURRENT_EXCEEDED_WARN
2782 Internal power supply <pwr-
supply>: Auxiliary inlet power
loss.
warn The power supply’s auxiliary power inlet has lost power. The
power supply still supplies power and is not shut down.
RMON_IPS_AUX_INLET_PWR_LOSS_WARN
2783 Internal power supply <pwr-
supply>: System power
temperature exceeded
threshold.
warn The power supply’s system power rail’s temperature has
exceeded the threshold. The power supply still supplies power
and is not shut down.
RMON_IPS_SYS_PWR_TEMP_EXCEEDED_WARN
2784 Internal power supply <pwr-
supply>: POE power temperature
exceeded threshold.
warn The power supply’s system power rail’s temperature has
exceeded the threshold. The power supply still supplies power
and is not shut down.
RMON_IPS_POE_PWR_TEMP_EXCEEDED_WARN
2785 Internal power supply <pwr-
supply>: Inlet air temperature
exceeded threshold.
warn The power supply’s inlet air temperature has exceeded a
threshold. The power supply still supplies power and is not shut
down.
RMON_IPS_INLET_TEMP_EXCEEDED_WARN
# Message Severity Description