Event Log Message Reference Guide 2013/06

4
Event Log Messages
59 STP: BPDU has MAX_AGE 0 from
port <port-num>
STP: BPDU has HELLO_TIME 0
from port <port-num>
STP:BPDU has FWD_DELAY 0
from port <port-num>
warning The switch received a BPDU packet with an invalid Max Age,
Hello Time, or Forward Delay value on the specified port. Check
to see if the parameter was misconfigured on the other bridge.
RMON_STP_BAD_BPDU
60 Bad reconfiguration request
<request>
warning An invalid configuration request has been made.
RMON_STP_BAD_DYNAMIC_REQ
61 --------------------- info Blank line
RMON_BOOT_BLANK_LINE
62 Management module <module-
num> went down without saving
crash information
info The specified management module crashed without saving a
crash record.
RMON_BOOT_NO_CRASH_RECORD
63 Mgmt Module <mod-num> went
down
info The specified management module was rebooted.
RMON_BOOT_CRASH_RECORD0
64 <crash- msg> info Text message explaining the reasons for a system crash, which
may include the type of crash (out of resources or bus error), task
name, filename and line number (bus address).
RMON_BOOT_CRASH_RECORD1
65 Boot-up selftest failed fatal Self test failed while switch is booting up.
RMON_BOOT_SELFTEST_FAILURE
66 System booted info System booted up.
RMON_BOOT_COMPLETE
67 Slot <slot-num> removed info The module in the specified slot has been removed.
RMON_CHASSIS_HOTSWAP_REMOVED
68 Slot <slot-num> inserted info A module has been inserted into the specified slot.
RMON_CHASSIS_HOTSWAP_SELFTEST0
69 Slot <slot-num> Hotswap Failure fatal A module hotswap failure occurred in the specified slot.
RMON_CHASSIS_HOTSWAP_FAILURE
70 Fan <fan-num>: Fan: <fan-state>
Failures: <num>
warning A fan (fan 1 or fan 2) has failed or a failed fan is no longer failing,
as indicated by the fan state (failure or OK). The number of times
that the fan failed is also displayed. In case of failure, the fan fail
LED is lit.
RMON_CHASSIS_FAN_STATUS
71 Power Supply <pwr-supply>:
Supply: <pwr-state>, Failures:
<num>
warning One of the following power conditions exists:
The redundant power-supply (RPS) is failing.
The RPS is operational but the main power supply is failing.
A failed power supply is no longer failing.
The state of the power supply (main or RPS) is indicated as failure
or OK. The number of times that the power supply failed is also
displayed. In case of failure, the power fail LED is lit.
RMON_CHASSIS_POWER_STATUS