Event Log Message Reference Guide 2013/06

91
Event Log Messages
3784 Invalid domain name provided by
DHCP Server on Primary VLAN
warning An invalid domain name was provided by the DHCP server.
RMON_DHCP_INVALID_DNS_SUFFIX
3785 Invalid DNS server address
provided by DHCP Server on
Primary VLAN
warning The DNS server address provided by the DHCP server on the
primary VLAN is invalid.
RMON_DHCP_INVALID_DNS_SVRADDR
3801 Mgmt module <module> -
Nonstop switching disabled
because of SW version
mismatch. Warm standby
enabled.
warn There is a software version mismatch between the management
modules. Non-stop switching is disabled and warm standby is
enabled.
RMON_SYSTEM_MGMT_OS_DIFF_WARM_STBY
3831 EEE cannot be enabled on <slot>
on this hardware revision.
warn EEE cannot be enabled on the specified slot on this hardware.
RMON_CHASSIS_SLOT_EEE_UNSUPPORTED
3841 <error message> fatal FPGA upgrade failed.
RMON_SSC_FPGA_UPGRADE_FAILED
3842 <message> info FPGA upgrade passed.
RMON_SSC_FPGA_UPGRADE_PASSED
4050 Distributed power to this switch
has changed to <num> watts by
%s
info External power supply power-share request is completed.
RMON_PPS_DISTRIBUTE_PWR_CHANGE
4051 Unable to distribute power as
requested. Reason: <reason>
warn Unable to perform power-share as requested.
RMON_PPS_DISTRIBUTE_PWR_REQ_FAIL
4052 External power supply
connection status changed from
<status> to <status>.
warn The external power supply connection status changed from
<previous state> to <current state>.
RMON_PPS_STATUS_CHANGE
4053 External power supply has been
restored to factory default.
info This message displays when the external power supply has been
restored to the factory default.
RMON_PPS_FAC_RESET_DONE
4054 There is a mismatch in power
supply ratings between external
power supply and this switch.
Configuration of external supply
will not be allowed.
warn There is a mismatch in power supply ratings between the external
power supply and the switch. The external power supply will not
be configured.
RMON_PPS_PSU_MISMATCH
4055 12v standby rail on external
power supply has failed.
warn The 12v standby rail on the external power supply has failed.
RMON_PPS_12V_STDBY_BAD
4056 Unable to communicate with
external power supply.
warn Unable to get i2c access to external power supply.
RMON_PPS_COMM_BAD
# Message Severity Description