F3215-HP Load Balancing Module High Availability Command Reference-6PW101

128
Syntax
standby track track-entry-number
undo standby track
Default
An interface is not associated with a track entry.
Views
Interface view
Default command level
2: System level
Parameters
track-entry-number: Specifies a track entry to be monitored by its number, which ranges from 1 to 1024.
Usage guidelines
This command and the standby interface command cannot be configured at the same time. If you have
configured the standby interface command on the active interface, you cannot configure the standby
track command on both the active interface and its standby interface. If you have associated an interface
with a track entry, you cannot configure the interface as the active interface or a standby interface.
One interface can be associated with one track entry. If you execute this command multiple times on one
interface, the most recent configuration takes effect.
You can associate an interface with a nonexistent track entry. The track function can take effect after the
track entry is created with the track command.
Examples
# Configure interface GigabitEthernet 0/1 to be associated with track entry 1.
<Sysname> system-view
[Sysname] interface gigabitethernet 0/1
[Sysname-GigabitEthernet0/1] standby track 1
Related commands
standby interface
track