F3215-HP Load Balancing Module High Availability Command Reference-6PW101

94
probe packet-number
Use probe packet-number to configure the number of packets to be sent in one UDP jitter or voice probe.
Use undo probe packet-number to restore the default.
Syntax
probe packet-number packet-number
undo probe packet-number
Default
An UDP jitter probe sends 10 packets and a voice probe sends 1000 packets.
Views
UDP jitter operation view, voice operation view
Default command level
2: System level
Parameters
packet-number: Specifies the number of packets to be sent per probe. The value is in the range of 10 to
1000 for the UDP jitter operation, and 10 to 60000 for the voice operation.
Examples
# Configure the UDP jitter probe to send 100 packets.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] probe packet-number 100
probe packet-timeout
Use probe packet-timeout to configure the timeout time for waiting for a response in the UDP jitter or
voice operation.
Use undo probe packet-timeout to restore the default.
Syntax
probe packet-timeout packet-timeout
undo probe packet-timeout
Default
The response timeout time in the UDP jitter operation is 3000 milliseconds, and the response timeout time
in the voice operation is 5000 milliseconds.
Views
UDP jitter, voice operation view
Default command level
2: System level