F3215-HP Load Balancing Module Network Management Command Reference-6PW101
14
Field Descri
p
tion
Type
Link type of the interface:
• A—Access.
• H—Hybrid.
• T—Trunk.
PVID Port VLAN ID.
Cause
Causes for the physical state of an interface to be DOWN. For more information,
see Table 7.
Table 7 Causes for the physical state of an interface to be DOWN
Field Descri
p
tion
Not connected
No physical connection exists (possibly because the network cable is
disconnected or faulty).
Administratively
The port was shut down with the shutdown command. To restore the physical
state of the interface, use the undo shutdown command.
Related commands
interface
duplex
Use duplex to set the duplex mode for an Ethernet interface.
Use undo duplex to restore the default duplex mode of the Ethernet interface.
Syntax
duplex { auto | full | half }
undo duplex
Default
Ethernet interfaces operate in auto negotiation mode.
Views
Ethernet interface view
Default command level
2: System level
Parameters
auto: Sets the interface to operate in auto negotiation mode.
full: Sets the interface to operate in full duplex mode.
half: Sets the interface to operate in half-duplex mode. This keyword is not available for the fiber combo
ports and 10-GE interfaces.
Examples
# Configure interface GigabitEthernet 0/1 to operate in full duplex mode.
<Sysname> system-view
[Sysname] interface gigabitethernet 0/1