F3215-HP Load Balancing Module System Management Command Reference-6PW101
65
Parameters
slot slot-number: Displays temperature information for a module.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see System Management Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Examples
# Display temperature information.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
hotspot 1 37 0 60 NA NA
Table 14 Command output
Field Descri
p
tion
System Temperature information
(degree centigrade)
Temperature information of system cards.
SlotNO Number of the slot in which the card resides.
Temperature Current temperature.
Lower limit Lower limit of temperature.
Warning-UpperLimit Warning temperature threshold.
Alarm-UpperLimit Alarming temperature threshold.
Shutdown-UpperLimit
Shut-down temperature threshold. When the sensor temperature reaches
this limit, the system shuts down automatically.
Related commands
temperature-limit
display flowengine-usage
Use display flowengine-usage to display the usage statistics for the flow engine.
Syntax
display flowengine-usage [ | { begin | exclude | include } regular-expression ]
Views
Any view