F3215-HP Load Balancing Module System Management Configuration Guide-6PW101
4
Login overview
This chapter describes the available login methods and their configuration procedures.
Login methods at a glance
For the first login, you can connect a terminal to the console port of the LB module to access the CLI or
use the username admin and password admin to access the Web interface of the LB module. After login,
you can configure other login methods, such as Telnet and SSH for remote access.
Table 1 Login methods
Lo
g
in method Default settin
g
and confi
g
uration re
q
uirements
Logging in to the CLI:
• Logging in through the console
port for the first time
By default, login through the console port is enabled, no username or
password is required, and the user privilege level is 3.
• Logging in through Telnet
By default, Telnet service is disabled. To use Telnet service, complete
the following configuration tasks:
• Enable the Telnet server function.
• Assign an IP address to a Layer 3 interface and make sure the
interface and the Telnet client can reach each other. By default, the
LB module has the IP address 192.168.0.1/24 configured for the
interface GigabitEthernet 0/1.
• Configure the authentication mode for VTY login users (scheme by
default).
• Configure the user privilege level of VTY login users (0 by default).
• Logging in through SSH
By default, SSH service is disabled. To use SSH service, complete the
following configuration tasks:
• Enable the SSH server function and configure SSH attributes.
• Assign an IP address to a Layer 3 interface and make sure the
interface and the SSH client can reach each other. By default, the
LB module has the IP address 192.168.0.1/24 configured for the
interface GigabitEthernet 0/1.
• Enable scheme authentication for VTY login users (scheme by
default).
• Configure the user privilege level of VTY login users (0 by default).
Logging in to the Web interface
By default, you can log in to the Web interface with the IP address
192.168.0.1/24, username admin, and password admin. (By
default, the LB module has the IP address 192.168.0.1/24
configured for the interface GigabitEthernet 0/1.)