F3215-HP Load Balancing Module System Management Configuration Guide-6PW101
144
# Use the save command to save the running configuration. (Details not shown.)
# Examine the storage medium on the LB module for space insufficiency. If the free space is not
sufficient for the patches, delete unused files. (Details not shown.)
# Download patch_hfw.bin from the TFTP server to the root directory of the LB module's storage
medium.
<LB> tftp 2.2.2.2 get patch_hfw.bin
# Install the patches.
<LB> system-view
[LB] patch install cfa0:
Patches will be installed. Continue? [Y/N]:y
Do you want to continue running patches after reboot? [Y/N]:y
Installing patches........
Installation completed, and patches will continue to run after reboot.
3. Use the display patch information command to verify that the patches have been installed and
running. (Details not shown.)