F3215-HP Load Balancing Module System Management Configuration Guide-6PW101
55
Command Effective s
y
stem time
Confi
g
uration exam
p
le
S
y
stem time
3
The original system time
outside the daylight
saving time range:
The system time does not
change until it falls into
the daylight saving time
range.
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
01:00:00 UTC Sat
01/01/2012.
The original system time
in the daylight saving time
range:
The system time increases
by summer-offset.
clock summer-time ss
one-off 00:30
2012/1/1 1:00
2012/8/8 2
03:00:00 ss Sat
01/01/2012.
If the original system time
plus summer-offset is
beyond the daylight saving
time range, the original
system time does not
change. After you disable
the daylight saving setting,
the system time
automatically decreases by
summer-offset.
1, 3
date-time outside the
daylight saving time
range:
date-time
clock datetime 1:00
2012/1/1
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
01:00:00 UTC Mon
01/01/2012.
date-time in the daylight
saving time range:
date-time + summer-offset
clock datetime 8:00
2012/1/1
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
10:00:00 ss Mon
01/01/2012.
If the date-time plus
summer-offset is outside the
daylight saving time range,
the system time equals
date-time. After you disable
the daylight saving setting,
the system time
automatically decreases by
summer-offset.
3, 1
(date-time outside the
daylight saving time
range)
date-time
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
clock datetime 1:00
2012/1/1
01:00:00 UTC Tue
01/01/2012.
3, 1
(date-time in the
daylight saving time
range)
date-time – summer-offset
outside the daylight
saving time range:
date-time – summer-offset
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
clock datetime 1:30
2012/1/1
23:30:00 UTC Sun
12/31/2012.
date-time – summer-offset
in the daylight saving time
range:
date-time
clock summer-time ss
one-off 1:00
2012/1/1 1:00
2012/8/8 2
clock datetime 3:00
2012/1/1
03:00:00 ss Mon
01/01/2012.