[LB-job-pc1] quit
# Create a job named pc2, and enter its view.
[LB] job pc2
# Configure the job to be executed in the view of GigabitEthernet 0/2.
[LB-job-pc2] view gigabitethernet 0/2
# Configure the LB module to enable GigabitEthernet 0/2 at 8:00 on working days every week.
[LB-job-pc2] time 1 repeating at 8:00 week-day mon tue wed thu fri command undo shutdown
# Configure the LB module to shut down GigabitEthernet 0/2 at 18:00 on working days every week.
[LB-job-pc2] time 2 repeating at 18:00 week-day mon tue wed thu fri command shutdown
[LB-job-pc2] quit
# Create a job named pc3, and enter its view.
[LB] job pc3
# Configure the job to be executed in the view of GigabitEthernet 0/3.
[LB-job-pc3] view gigabitethernet 0/3
# Configure the LB module to enable GigabitEthernet 0/3 at 8:00 on working days every week.
[LB-job-pc3] time 1 repeating at 8:00 week-day mon tue wed thu fri command undo shutdown
# Configure the LB module to shut down GigabitEthernet 0/3 at 18:00 on working days every week.
[LB-job-pc3] time 2 repeating at 18:00 week-day mon tue wed thu fri command shutdown
[LB-job-pc3] quit
# Display information about scheduled jobs.
[LB] display job
Job name: pc1
Specified view: gigabitethernet 0/1
Time 1: Execute command undo shutdown at 08:00 Mondays Tuesdays Wednesdays Thursdays
Fridays
Time 2: Execute command shutdown at 18:00 Mondays Tuesdays Wednesdays Thursdays Fridays
Job name: pc2
Specified view: gigabitethernet 0/2
Time 1: Execute command undo shutdown at 08:00 Mondays Tuesdays Wednesdays Thursdays
Fridays
Time 2: Execute command shutdown at 18:00 Mondays Tuesdays Wednesdays Thursdays Fridays
Job name: pc3
Specified view: Gigabitethernet 0/3
Time 1: Execute command undo shutdown at 08:00 Mondays Tuesdays Wednesdays Thursdays
Fridays
Time 2: Execute command shutdown at 18:00 Mondays Tuesdays Wednesdays Thursdays Fridays
Configuring temperature thresholds for a device
You can set the temperature threshold to monitor the temperature of a device. When the temperature
reaches the threshold, the device generates alarms.
To configure the temperature threshold: