F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices Access Control Configuration Guide-6PW100
203
The following matrixes show the service types and hardware compatibility:
Hardware DVPN
service com
p
atible
F1000-A-EI/F1000-S-EI No
F1000-E Yes
F5000 Yes
Firewall module Yes
U200-A No
U200-S No
Hardware Portal service com
p
atible
F1000-A-EI/F1000-S-EI Yes
F1000-E Yes
F5000 No
Firewall module Yes
U200-A Yes
U200-S Yes
424BLocal user configuration task list
Task Remarks
720H
Configuring local user attributes Required.
721H
Configuring user group attributes Optional.
722H
Displaying and maintaining local users and local user groups Optional.
425BConfiguring local user attributes
Follow these guidelines when you configure local user attributes:
• When the password control feature is enabled globally by using the password-control enable
command, local user passwords are not displayed.
• If the user interface authentication mode set by the authentication-mode command in user interface
view is AAA (scheme), which commands a login user can use after login depends on the privilege
level authorized to the user. If the user interface authentication mode is password (password) or no
authentication (none), which commands a login user can use after login depends on the level
configured for the user interface by using the user privilege level command in user interface view.
For an SSH user using public key authentication, which commands are available depends on the
level configured for the user interface. For more information about user interface authentication
mode and user interface command level, see Fundamentals Configuration Guide.
• You cannot delete a local user who is the only security log manager in the system, nor can you
change or delete the security log manager role of the user. To do so, you must specify a new security
log manager first.
To configure local user attributes: