F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices Getting Started Command Reference-6PW100

65
Parameters
power-id: Displays information about the specified power supply, where power-id represents the power
supply number..
The following matrix shows the value range for the power-id argument on different firewalls and UTM
devices:
Hardware Value ran
g
e
F1000-A-EI/F1000-S-EI 1 to 2
F1000-E 1
F5000 1 to 2
Firewall module No power supply. This command is not supported.
U200-A 1
U200-S 1
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the chapter on CLI in Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Examples
# Display power supply information.
<Sysname> display power
Power Information:
Power 1 Status: AbNormal
Power 2 Status: Normal
display reboot-type
Use display reboot-type to display the mode of the last reboot.
Syntax
display reboot-type [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
2: System level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the chapter on CLI in Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.