F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices Getting Started Command Reference-6PW100
70
Table 17 Command output
Field Descri
p
tion
transceiver information Transceiver module information.
Transceiver Type Transceiver module type.
Connector Type
Connector type options:
• LC—1.25 mm/RJ-45 fiber connector developed by Lucent.
• RJ-45.
Wavelength(nm)
• Fiber transceiver: central wavelength (in nm) of the transmit
laser. If the transceiver supports multiple wavelengths, every
two wavelength values are separated by a comma.
• Copper transceiver: displayed as N/A.
Transfer Distance(xx)
Transfer distance, with xx representing km for single-mode
transceiver modules and m for other transceiver modules. If the
transceiver module supports multiple transfer media, every two
transfer distance values are separated by a comma. The
corresponding transfer medium is included in the bracket
following the transfer distance value. The following are the
supported transfer media:
• 9 um—9/125 um single-mode fiber.
• 50 um—50/125 um multi-mode fiber.
• 62.5 um—62.5/125 um multi-mode fiber.
• TP—Twisted pair.
Digital Diagnostic Monitoring
Support for the digital diagnosis function:
• YES—supported.
• NO—not supported.
Vendor Name Vendor name.
Ordering Name Product code.
display transceiver alarm
Use display transceiver alarm to display alarms present on transceiver modules.
Syntax
display transceiver alarm interface [ interface-type interface-number ] [ | { begin | exclude | include }
regular-expression ]
Views
Any view
Default command level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays the alarms that are present on the transceiver
module in an interface. The interface-type interface-number argument specifies an interface by its type
and number. If no interface is specified, this command displays present alarm information for the
transceiver modules in all interfaces.