F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices Getting Started Command Reference-6PW100

71
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the chapter on CLI in Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
If no error occurs, None is displayed. Table 18 describes the transceiver module alarms that might occur.
Table 18 Common transceiver module alarms
Field Remarks
SFP/SFP+
RX loss of signal Incoming (RX) signal is lost.
RX power high Incoming (RX) power is high.
RX power low Incoming (RX) power is low.
TX fault Transmit (TX) fault.
TX bias high TX bias current is high.
TX bias low TX bias current is low.
TX power high TX power is high.
TX power low TX power is low.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
The port does not support the transceiver type.
XFP
RX loss of signal Incoming (RX) signal is lost.
RX not ready RX is not ready.
RX CDR loss of lock RX clock cannot be recovered.
RX power high RX power is high.
RX power low RX power is low.
TX not ready TX is not ready.
TX fault TX fault.