Related commands
display environment (advanced)
temperature-limit (basic)
Use temperature-limit to set basic temperature alarm thresholds for a card.
Use undo temperature-limit to restore the default.
Syntax
temperature-limit slot-number lower-value upper-value
undo temperature-limit slot-number
Default
The lower threshold is 0°C (32°F), and the upper threshold is 50°C (122°F).
Views
System view
Default command level
2: System level
Parameters
slot-number: See Table 23.
lower-value: Lower temperature threshold in Celsius degrees. The value ranges from 0°C to 70°C (32°F
to 158°F).
upper-value: Upper temperature threshold in Celsius degrees. The value ranges from 20°C to 90°C
(68°F to 194°F).
The upper threshold must be larger than the lower threshold.
Usage guidelines
Table 23 Hardware compatibility for this command and the
slot-number
argument
Hardware Command com
p
atible
Ar
g
ument com
p
atible
F1000-A-EI/F1000-S-EI No No
F1000-E No No
F5000 No No
Firewall module No No
U200-A No No
U200-S Yes Yes (0 for the PCB)
Examples
# Configure card 1 to use the lower temperature threshold 10°C (50°F) and the upper temperature
threshold 75°C (167°F).
<Sysname> system-view
[Sysname] temperature-limit 1 10 75
Setting temperature limit succeeded.