F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices Network Management Configuration Guide-6PW100

15
1070BConfiguration restrictions and guidelines
On an interface that is physically down, you can only perform internal loopback testing. On an
interface administratively shut down, you cannot perform internal or external loopback testing.
The speed, duplex, mdi, and shutdown commands are not available during loopback testing.
During loopback testing, the Ethernet interface operates in full duplex mode. When you disable
loopback testing, the port returns to its duplex setting.
1071BConfiguration procedure
To enable loopback testing on an Ethernet interface:
Ste
p
Command
Remarks
20. Enter system view. system-view N/A
21. Enter Ethernet interface view.
interface interface-type
interface-number
N/A
22. Enable loopback testing.
loopback { external | internal }
By default, loopback testing is
disabled.
373BConfiguring the link mode of an Ethernet interface
Depending on the hardware structure of interface modules, for a device, some interfaces can operate
only as Layer 2 Ethernet interfaces (in bridge mode), some can operate only as Layer 3 Ethernet
interfaces (in route mode), but others can operate either as Layer 2 or Layer 3 Ethernet interfaces (you
can set the link mode to bridge or route).
You can configure the link mode in system view or in Ethernet interface view, which produces the same
result. The link mode configuration in system view applies to multiple interfaces, and the link mode
configuration in interface view applies only to the current interface.
1072BConfiguration restrictions and guidelines
After you change the link mode of an Ethernet interface, all settings of the Ethernet interface are
restored to their defaults under the new link mode.
The link mode configuration for an Ethernet interface in system view and in interface view
supersedes each other.
1073BConfiguration procedure
To change the link mode of the specified Ethernet interfaces in system view:
Ste
p
Command
23. Enter system view. system-view
24. Change the link mode of the specified Ethernet
interfaces.
port link-mode { bridge | route } interface-list
To change the link mode of an Ethernet interface:
Ste
p
Command
25. Enter system view.
system-view
26. Enter Ethernet interface view. interface interface-type interface-number