F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices System Management and Maintenance Command Reference-6PW100

222
Default command level
3: Manage level
Parameters
interface interface-type interface-number: Specifies a source interface by its type and number.
ipv6 ipv6-address: Specifies a source IPv6 address.
Usage guidelines
To make sure the Stelnet client and the Stelnet server can communicate with each other, and to improve
the manageability of Stelnet clients in the authentication service, HP recommends you to specify a
loopback interface or dialer interface as the source interface.
The following matrix shows the ssh client ipv6 source command and firewalls and UTM devices
compatibility:
Hardware Command com
p
atible
F1000-A-EI/F1000-S-EI Yes
F1000-E Yes
F5000 Yes
Firewall module Yes
U200-A Yes
U200-S No
Examples
# Specify the source IPv6 address as 2:2::2:2 for the Stelnet client.
<Sysname> system-view
[Sysname] ssh client ipv6 source ipv6 2:2::2:2
Related commands
display ssh client source
ssh client source
Use ssh client source to specify the source IPv4 address or source interface of the Stelnet client.
Use undo ssh client source to remove the configuration.
Syntax
ssh client source { interface interface-type interface-number | ip ip-address }
undo ssh client source
Default
An Stelnet client uses the IP address of the interface specified by the route of the device to access the
Stelnet server.
Views
System view