F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices System Management and Maintenance Configuration Guide-6PW100

123
Nominal frequency: 64.0000 Hz
Actual frequency: 64.0000 Hz
Clock precision: 2^7
Clock offset: 0.0000 ms
Root delay: 31.00 ms
Root dispersion: 1.05 ms
Peer dispersion: 7.81 ms
Reference time: 14:53:27.371 UTC Sep 19 2005 (C6D94F67.5EF9DB22)
The output shows that Device B has synchronized to Device A. The stratum level of Device B is 3,
and that of Device A is 2.
# Display NTP session information for Device B, which shows that an association has been set up
between Device B and Device A.
[DeviceB] display ntp-service sessions
source reference stra reach poll now offset delay disper
**************************************************************************
[12345] 1.0.1.11 127.127.1.0 2 63 64 3 -75.5 31.0 16.5
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations : 1
250BConfiguring the NTP symmetric mode
426BNetwork requirements
Perform the following configurations to synchronize time among devices:
As shown in
841HFigure 53, the local clock of Firewall A is to be configured as a reference source, with
the stratum level 2.
The local clock Firewall C is to be configured as a reference source, with the stratum level 1.
Firewall B operates in client mode and Firewall A is to be used as the NTP server of Device B.
Firewall C operates in symmetric-active mode and Firewall B acts as the peer of Firewall C.
Figure 53 Network diagram
427BConfiguration procedure
1. Set the IP address for each interface as shown in 842HFigure 53. (Details not shown.)