F3726, F3211, F3174, R5135, R3816-HP Firewalls and UTM Devices System Management and Maintenance Configuration Guide-6PW100

208
Ste
p
Command
Remarks
2. Set the maximum
number of concurrent
sessions for the default
VD.
session max-entries max-entries
By default, the maximum number of
concurrent sessions for the default VD
equals the maximum number of sessions
supported by the physical device.
To set the maximum number of concurrent sessions for a non-default VD:
Ste
p
Command
Remarks
1. Enter system view.
system-view
N/A
2. Log in to the VD.
switchto vd vd-name Optional.
3. Set the maximum
number of concurrent
sessions for the VD.
session max-entries max-entries
By default, the maximum number of
concurrent sessions for a non-default
VD equals the maximum number of
sessions specified for the VD by using
the limit-resource session
max-entries command.
317BVD configuration example
479BNetwork requirements
Virtualize Firewall into two VDs and use the two VDs as the gateways for enterprise A and enterprise B
so that:
Each enterprise has its own Layer 3 Ethernet interface.
Enterprise A can use VLAN 100 to VLAN 205, and can have up to 100000 sessions.
Enterprise B can use VLAN 50 to VLAN 80, VLAN 400, and VLAN 500 to VLAN 530, and can
have up to 200000 sessions.
Figure 100 Network diagram
480BConfiguration procedure
# Create a VD with the name vda and ID 2.
<Firewall> system-view
[Firewall] vd vda id 2
Firewall
Internet
Enterprise B
LAN 1
Enterprise A
vda vdb
GE1/1 GE1/2