HP A6600 SSL VPN Card Manual-6P102

Manual Version: 6P102-20111130 BOM:
3123A0F6
Part number: 5998-2240
ii
Table 2 SPE-SSL-200 specifications
Item S
p
ecification
Interface
One console port
Two USB interfaces (reserved)
Interface transmission speed Console port: 9600 bps to 115200 bps (default: 9600 bps)
Cable and maximum
transmission distance
Console port: Asynchronous serial cable with maximum transmission distance
of 15 m (49.21 ft)
CF card and slot
One CF card slot. By default, no CF card is configured. You can purchase
a CF card as needed.
The CF card slot supports an external CF card of 256 MB, 512 MB, or 1 GB.
Applied to HP A6604, A6608, and A6616
3 Installing and removing the SPE-SSL-200
ARNING!
Wear an ESD-preventive wrist strap and ESD-preventive gloves before installing or removing the
module, and make sure that the ESD-preventive wrist strap is properly grounded.
Avoid touching any components on the PCB and hold the PCB by its edge when installing and removin
g
the module.
NOTE:
The SPE-SSL-200 is hot swappable. That is, you can remove the module from a router when the router is
powered on.
3.1
Installing the SPE-SSL-200
1. Locate the slot where you will install the SPE-SSL-200, and remove the blank panel from the
position. This manual describes installing the SPE-SSL-200 to slot 2.
2. Push the module (with the components facing on) into the slot along the guide rails until the
positioning hole of the module is seated onto the positioning pin on the backplane. Push the ejector
levers inward to lock the module in place.
3. Fasten the captive screws on the module with a Philips screwdriver.