HP Security Modules Software Upgrade Guide-6PW103
23
Figure 13 Sending file dialog box
After the file is downloaded, the following information is displayed on the configuration terminal:
Download successfully!
10129792 bytes downloaded!
NOTE:
• The size of an application is often over 10 MB. Even if the baud rate is set to 115200 bps, it usually takes
about 30 minutes to upgrade the application through the serial interface. Therefore, you are
recommended to upgrade applications through an Ethernet interface.
• If you want the Security module to use the downloaded file, you need to specify the file for the next boot.
For related information, see “Specifying Files”.
.
Upgrading the BootWare Program
Select 7 on the main menu (see “Main Menu”) to enter the BootWare operation submenu, where you can
perform all operations related to the BootWare program. For more information about the BootWare
operation submenu, see “BootWare Operation Submenu”.
The following example shows how to upgrade the entire BootWare program:
Step1 Modify the baud rate of the serial interface to improve the upgrade speed (for more information, see
“Modifying Serial Interface Parameters”)
and then select 3 on the BootWare operation submenu. The
following information is displayed:
===========<BOOTWARE OPERATION SERIAL SUB-MENU>==============
| <1> Update Full BootWare |
| <2> Update Extended BootWare |
| <3> Update Basic BootWare |
| <4> Modify Serial Interface Parameter |
| <0> Exit To Main Menu |
=============================================================
Enter your choice(0-4):