HP Security Modules Software Upgrade Guide-6PW103

27
NOTE:
To use the default parameter after a colon, press Enter directly.
If the Ethernet port parameter settin
g
s fail to pass CRC check, the system adopts the default settin
g
s and
displays “Check net params crc error, use the default value.
Step3 After the above configurations, you will return to the Ethernet submenu, where you can select 2 to
upgrade the main application file.
Loading................................... done
10129712 bytes downloaded!
Updating File cfa0:/main.bin
.........
Update Success!
CAUTION:
If the application file name you entered already exists on the CF card,The file exists, will you overwrite
it? [Y/N] will be prompted. If you enter Y, the application file on the CF card will be directly overwritten.
The upgraded application file will become the only main application file.
Make sure that the available space on the CF card is enou
g
h. Otherwise, “The free space isn’t enou
g
h”
will be prompted.
If you want the Security module to use the downloaded file, you need to specify the file for the next boot.
For related information, see “Specifying Files”.
Step4 After the main application file is upgraded, select 0 to return to the main menu, where you can select 1
on the main menu to reboot the Security module from the CF card.
Upgrading Application Files with TFTP at the CLI
Step1 Set up an upgrade environment.
Connect the PC to an Ethernet interface (for example, GigabitEthernet 0/1) on a Security and ensure the
connectivity between them.
The Security module serves as the TFTP client while the PC serves as the TFTP server.
Use a crossover Ethernet cable to connect Ethernet interface GigabitEthernet 0/1 on the Security
module to the PC.
Configure IP addresses for the TFTP server and client and ensure that they are on the same network
segment. In this example, the IP address of the TFTP server (PC) is 192.168.80.200 and that of the
TFTP client (GigabitEthernet 0/1) is 192.168.80.10. Use the ping command to check the
connectivity between them.
Enable the terminal emulation program on the PC.
NOTE:
For a Security module except SSL VPN modules, to up
g
rade application files usin
g
the CLI, you need to
only directly connect the PC to the Security module.
For the SSL VPN module, because the module does not provide service ports on its panel, you need to
use a crossover Ethernet cable to connect the service port (such as Gi
g
abitEthernet 3/0/1) of the switch
or router to the PC, and guarantee that the Security SSL VPN module can communicate with the PC.
Step2 View the files and the available space on the CF card.