R3166-R3206-HP High-End Firewalls Getting Started Command Reference-6PW101

50
****************************************************************************
* Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P. *
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
****************************************************************************
User interface con0 is available.
Please press ENTER.
# Disable the display of copyright information.
<Sysname> system-view
[Sysname] undo copyright-info enable
If a user logs in to the firewall through Telnet, the following information is displayed:
<Sysname>
If a user has already logged in through the console port, and then quits user view, the following
information is displayed:
User interface con0 is available.
Please press ENTER.
display clock
Syntax
display clock
View
Any view
Default level
1: Monitor level
Parameters
None
Description
Use the display clock command to view the current system time and date.
The current system time and date are decided by the clock datetime, clock summer-time one-off (or clock
summer-time repeating), and clock timezone commands. For more information about how the system
time and date are decided, see Getting Started Guide.
Related commands: clock datetime, clock summer-time one-off, clock summer-time repeating, and
clock timezone.
Examples
# Display the current time and date.
<Sysname> display clock