R3166-R3206-HP High-End Firewalls Getting Started Command Reference-6PW101
61
Default level
1: Monitor level
Parameters
power-id: Displays the information of the specified PSU, where power-id represents the PSU number. If
this argument is not provided, this command displays information about all PSUs.
Description
Use the display power command to display information about PSUs on the firewall.
Examples
# Display information about PSUs on the firewall.
<Sysname> display power
Power 0 State: Normal
Table 15 Output description
Field Descri
p
tion
Power PSU number
State
PSU state:
• Normal
• Absent
• Fault
display reboot-type
Syntax
display reboot-type
View
Any view
Default level
2: System level
Parameters
None
Description
Use the display reboot-type command to display the reboot mode of the firewall.
Examples
# Display the reboot mode of the firewall.
<Sysname> display reboot-type
The rebooting type this time is: Cold
The output shows that the last reboot mode of the firewall is Cold boot (cold boot will restart a firewall by
powering it off and then powering it on). (The display of Warm represents a warm boot, which means to
restart a firewall by using the commands like reboot).