R3166-R3206-HP High-End Firewalls Getting Started Command Reference-6PW101

64
RX loss of signal
RX power low
Table 16 Output description
Field Descri
p
tion
transceiver current alarm information Current alarm information of the transceiver
RX loss of signal Incoming (RX) signal is lost.
RX power low Incoming (RX) power level is low.
display transceiver diagnosis
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
View
Any view
Default level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays the currently measured value of digital diagnosis
parameters of the HP customized anti-spoofing pluggable optical transceiver plugged in the specified
interface. interface-type interface-number represents interface type and interface number. If it is not
specified, the command displays the currently measured value of digital diagnosis parameters of HP
customized anti-spoofing pluggable optical transceivers in all the interfaces.
Description
Use the display transceiver diagnosis command to display the currently measured value of digital
diagnosis parameters of HP customized anti-spoofing pluggable optical transceivers.
Examples
# Display the currently measured value of the digital diagnosis parameters of the HP customized
anti-spoofing pluggable optical transceiver plugged in interface GigabitEthernet 0/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 0/2
GigabitEthernet0/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 17 Output description
Field Descri
p
tion
transceiver diagnostic information
Digital diagnosis information of the transceiver plugged in
the interface
Current diagnostic parameters Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C, with the
precision to 1°C.