reaction item-num: Specifies the reaction entry to be associated with the track entry. item-num is the
reaction entry ID, in the range 1 to 10.
delay: Specifies that the track module notifies the application modules of the track entry status change
after a specified delay time. If this keyword is not provided, the track module notifies the application
modules immediately when the track entry status changes.
negative negative-time: Specifies the delay time for the track module to notify the application modules
that the status of the track entry changes to Negative. negative-time represents the delay time, ranging
from 1 to 300, in seconds.
positive positive-time: Specifies the delay time for the track module to notify the application modules that
the status of the track entry changes to Positive. positive-time represents the delay time, ranging from 1 to
300, in seconds.
Description
Use the track nqa command to create the track entry to be associated with the specified reaction entry
of the NQA test group, and specify the delay time for the track module to notify the application modules
when the status of the track entry changes.
Use the undo track command to remove the created track entry.
By default, no track entry to be associated with the track entry is created.
After a track entry is created, you cannot modify the content associated with the track entry. You
need to remove the track entry, and then reconfigure it.
After a track entry is created, you can use the track nqa delay command to modify the delay time
for the track module to notify the application modules of the track entry status change.
Related commands: nqa, reaction, and display track.
Examples
# Create track entry 1 to associate it with reaction entry 3 of the NQA test group (admin-test).
<Sysname> system-view
[Sysname] track 1 nqa entry admin test reaction 3
track interface
Syntax
track track-entry-number interface interface-type interface-number [ delay { negative negative-time |
positive positive-time } * ]
undo track track-entry-number
View
System view
Default level
2: System level
Parameters
track-entry-number: track entry ID, in the range 1 to 1024.
interface-type interface-number: Type and number of the interface to be monitored.