R3166-R3206-HP High-End Firewalls High Availability Command Reference-6PW101

44
Default level
2: System level
Parameters
interval: Interval between two consecutive tests, in milliseconds, in the range 0 to 604800000. If the
interval is 0, it indicates that only one test is performed, and no statistics are generated.
Description
Use the frequency command to configure the interval between two consecutive tests for a test group.
Use the undo frequency command to restore the default.
By default, the interval between two consecutive voice tests is 60000 milliseconds, and the interval
between two consecutive tests of other types is 0 milliseconds, that is, only one test is performed.
After you use the nqa schedule command to start an NQA test, one test is started at interval.
If the last test is not completed when the interval specified by the frequency command is reached, a new
test is not started.
Examples
# Configure the interval between two consecutive tests as 1000 milliseconds.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] frequency 1000
history-record enable
Syntax
history-record enable
undo history-record enable
View
Any NQA test type view
Default level
2: System level
Parameters
None
Description
Use the history-record enable command to enable the saving of history records of an NQA test group.
Use the undo history-record enable command to disable the history records saving function.
By default, history records of an NQA test group are not saved.
If the history records saving function is enabled, the system saves the history records. You can view
the history records of the NQA test group using the display nqa history command.
If the history records saving function is disabled, the system does not save the history records of the
NQA test group and the existing history records will be also removed.
Related commands: display nqa history.